BMXNV - V-LUBE G

Product Identification

Product ID:V-LUBE G
MSDS Date:12/01/1988
FSC:9150
NIIN:00N028046
MSDS Number: BMXNV

Responsible Party
PENNWALT CORP. STOKES EQUIPMENT DIVISION
5500 TABOR ROAD
PHILADELPHIA, PA 19120-2124
US

Emergency Phone: 800-424-9300

Info Phone: 215-831-5400

Preparer: RICHARD MAUNZ

Cage: 57847

Contractor
PENNWALT CORP. STOKES EQUIPMENT DIVISION
PHILADELPHIA, PA 19120-2124 US

Telephone: 800-424-9300

Cage: 57847

Ingredients

MINERAL OIL, PETROLEUM DISTILLATES, SOLVENT-REFINED

CAS: 64741-88-4

RTECS: PY8040500

Fraction By Weight: 80-100%

OSHA PEL 5 MG/M3 (OIL MIST)

ACGIH TLV: 5 MG/M3 (OIL MIST)


ETHYLENE PROPYLENE COPOLYMER

CAS: 9010-79-1

Fraction By Weight: 0-5%


ZINC DIALKYL DITHIOHOSPHATE

CAS: 68457-79-4

Fraction By Weight: 0-5%


MAGNESIUM SULFONATE

CAS: 61789-87-5

Fraction By Weight: 0-5%


POLY-BUTENYLAMIDE; (POLY-BUTONYLAMIDE)

Fraction By Weight: 0-5%


METHACRYLATE COPOLYMERS

Fraction By Weight: 0-5%


CALCIUM PHENATE

CAS: 68855-45-8

Fraction By Weight: 0-5%


SODIUM PETROLEUM SULFONATE

CAS: 68608-26-4

RTECS: WR7150000

Fraction By Weight: 0-5%

OSHA PEL 5 MG/M3 AS OIL MIST

ACGIH TLV: 5 MG/M3 AS OIL MIST

Hazards

LD50 LC50 Mixture:LD50:(RAT) >15 G/KG
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:(ACUTE) SKIN: PRACTICALLY NON-TOXIC IF
ABSORBED. MILD IRRITATION WITH PROLONGED OR REPEATED CONTACT. EYE:
MAY CAUSE MILD IRRITATION. INHAL: NO ACUTE EFFECTS EXPECTED TO
TWICE EXPOSURE LIMIT. (CHRONIC) INHAL OF OIL MIST MAY LEAD TO
LIPID (OR CHEMICAL) PNEUMONITIS. INGEST: PRACTICALLY NON-TOXIC.
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:NONE SPECIFIED BY MANUFACTURER.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:INGEST: DO NOT INDUCE VOMITING. GIVE PLENTY OF WATER. GET
MEDICAL ATTENTION. SKIN: FLUSH WITH SOAP AND WATER. CONTAMINATED
CLOTHING - REMOVE AND LAUNDER. EYE: FLUSH WITH PLENTY OF WATER FOR
AT LEAST 1 5 MINUTES. GET MEDICAL ATTENTION IF IRRITATION PERSISTS.
INHAL: REMOVE TO FRESH AIR.

Fire Fighting

Flash Point Method:COC
Flash Point:420F,216C
Extinguishing Media:WATER-FOG, CO*2, DRY CHEMICAL, FOAM.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA & FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:NONE EXPECTED.

Accidental Release

Spill Release Procedures:ABSORB WITH SAND OR INERT MATERIAL. SWEEP OR
SCOOP UP AND REMOVE.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:WASH THOROUGHLY AFTER HANDLING. DO NOT
GET IN EYES, ON SKIN OR CLOTHING. DO NOT BREATHE DUST, VAPOR, MIST,
GAS.
Other Precautions:NFPA CLASS IIIB STORAGE.

Exposure Controls

Respiratory Protection:NIOSH/MSHA APPROVED FILTER - DUST, FUME, MIST IF
MISTING OCCURS.
Ventilation:USE WITH ADEQUATE VENTILATION.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:NOT APPLICABLE.
Work Hygienic Practices:WASH THOROUGHLY AFTER HANDLING.
Supplemental Safety and Health
NONE SPECIFIED BY MANUFACTURER.

Chemical Properties

HCC:V6
Vapor Pres:NIL @ 20C
Vapor Density:12+
Spec Gravity:0.88
Evaporation Rate & Reference:1000XSLOWER(ETHER = 1)
Solubility in Water:NIL
Appearance and Odor:DARK AMBER FLUID, ENGINE OIL ODOR.
Percent Volatiles by Volume:NIL

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZERS.
Stability Condition to Avoid:OPEN FLAMES.
Hazardous Decomposition Products:OXIDES OF SULPHUR, PHOSPHORUS, AND
ZINC. CO AND ASPHYXIANTS.

Disposal

Waste Disposal Methods:DO NOT FLUSH TO DRAIN/STORM SEWER. CONTRACT TO
AUTHORIZED DISPOSAL SERVICE. DISPOSAL MUST BE IN ACCORDANCE WITH
FEDERAL, STATE AND LOCAL REGULATIONS .

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.